Skip to main content.

9 Site G

9.1 Introduction

Sampling was carried out at Site G on 26 and 27 March 2003. Samples were collected from the induction furnace baghouse discharge to determine the concentration and mass emission of PCDD and PCDF present in the gases discharged to the atmosphere.

The sampling ports were after the baghouse and were at least 5 stack diameters from any disturbance to the flow.

Details of the sampling date, times and stack dimensions are:

  • Sample date and time:
    • Sample 1: 26 March 2003, 9:42-14:46
    • Sample 2: 27 March 2003, 6:32-10:00
  • Stack dimensions: 0.575 metre diameter circular duct.

9.2 Results

Table 9.1: Particulate emissions from induction furnace

Sample Sample mass
(g)
Particulate emissions
(mg/m3, dry, 0°C, 1 Atm) (kg/h)

1

0.0017

0.6

0.0017

2

0.0003

0.1

0.00044

Average

 

0.3

0.0010

Table 9.2: Average stack gas conditions at the induction furnace sampling point

View average stack gas conditions at the induction furnace sampling point (large table)

Table 9.3: Results of isokinicity for induction furnace

Sample Actual sample volume
(m3, 0°C, 1 Atm, dry)
Calculated sample volume
(m3, 0°C, 1 Atm, dry)
Isokinicity
(%)

1

3.0647

3.0638

100%

2

2.1362

2.1003

102%

All samples are within the required isokinicity range of 100 ± 10%.

Table 9.4: Combustion gas results

CO
(mg/m3)
SO2
(mg/m3)
NO
(mg/m3)
O2
(%)
NO2
(mg/m3)

<11

<25

<12

21.1

<9

Table 9.5: Summary results from induction furnace sample 1 particulate and rinses

View summary results from induction furnace sample 1 particulate and rinses (large table)

Table 9.6: Results from induction furnace (individual congeners sample 1 particulate and rinses)

View results from induction furnace (individual congeners sample 1 particulate and rinses) (large table)

Table 9.7: Summary results from induction furnace sample 1 gaseous (trap)

View summary results from induction furnace sample 1 gaseous (trap) (large table)

Table 9.8: Results from induction furnace (individual congeners sample 1 gaseous (trap)

View results from induction furnace (individual congeners sample 1 gaseous (trap) (large table)

Table 9.9: Summary results from induction furnace sample 2 particulate and gaseous

View summary results from induction furnace sample 2 particulate and gaseous (large table)

Table 9.10: Results from induction furnace (individual congeners sample 2 particulate and gaseous)

View results from induction furnace (individual congeners sample 2 particulate and gaseous) (large table)