Sampling was carried out at Site G on 26 and 27 March 2003. Samples were collected from the induction furnace baghouse discharge to determine the concentration and mass emission of PCDD and PCDF present in the gases discharged to the atmosphere.
The sampling ports were after the baghouse and were at least 5 stack diameters from any disturbance to the flow.
Details of the sampling date, times and stack dimensions are:
Table 9.1: Particulate emissions from induction furnace
| Sample | Sample mass (g) |
Particulate emissions | |
|---|---|---|---|
| (mg/m3, dry, 0°C, 1 Atm) | (kg/h) | ||
|
1 |
0.0017 |
0.6 |
0.0017 |
|
2 |
0.0003 |
0.1 |
0.00044 |
|
Average |
0.3 |
0.0010 |
|
Table 9.2: Average stack gas conditions at the induction furnace sampling point
View average stack gas conditions at the induction furnace sampling point (large table)
Table 9.3: Results of isokinicity for induction furnace
| Sample | Actual sample volume (m3, 0°C, 1 Atm, dry) |
Calculated sample volume (m3, 0°C, 1 Atm, dry) |
Isokinicity (%) |
|---|---|---|---|
|
1 |
3.0647 |
3.0638 |
100% |
|
2 |
2.1362 |
2.1003 |
102% |
All samples are within the required isokinicity range of 100 ± 10%.
Table 9.4: Combustion gas results
| CO (mg/m3) |
SO2 (mg/m3) |
NO (mg/m3) |
O2 (%) |
NO2 (mg/m3) |
|---|---|---|---|---|
|
<11 |
<25 |
<12 |
21.1 |
<9 |
Table 9.5: Summary results from induction furnace sample 1 particulate and rinses
View summary results from induction furnace sample 1 particulate and rinses (large table)
Table 9.6: Results from induction furnace (individual congeners sample 1 particulate and rinses)
Table 9.7: Summary results from induction furnace sample 1 gaseous (trap)
View summary results from induction furnace sample 1 gaseous (trap) (large table)
Table 9.8: Results from induction furnace (individual congeners sample 1 gaseous (trap)
View results from induction furnace (individual congeners sample 1 gaseous (trap) (large table)
Table 9.9: Summary results from induction furnace sample 2 particulate and gaseous
View summary results from induction furnace sample 2 particulate and gaseous (large table)
Table 9.10: Results from induction furnace (individual congeners sample 2 particulate and gaseous)