On 6 March 2003, sampling was carried out at Site C. Samples were collected from the induction furnace baghouse discharge to determine the concentration and mass emission of PCDD and PCDF present in the gases discharged to the atmosphere.
The sampling point was after the baghouse in a vertical section of duct and at least three duct diameters from any disturbance to the flow. The sampling point was accessed from scaffolding.
Details of the sampling date, times and stack dimensions are:
Table 5.1: Particulate emissions from induction furnace
| Sample |
Sample mass (g) |
Particulate emissions | |
|---|---|---|---|
|
(mg/m3, dry, 0°C, 1 Atm) |
(kg/h) | ||
|
1 |
0.001 |
<0.6 |
<0.02 |
|
2 |
0.001 |
<0.6 |
<0.02 |
|
Average |
<0.6 |
<0.02 |
|
Note: The sample mass was less than the limit of detection.
Table 5.2: Average stack gas conditions at the induction furnace sampling point
View average stack gas conditions at the induction furnace sampling point (large table)
Table 5.3: Results of isokinicity for induction furnace
| Sample |
Actual sample volume (m3, 0°C, 1 Atm, dry) |
Calculated sample volume (m3, 0°C, 1 Atm, dry) |
Isokinicity (%) |
|---|---|---|---|
|
1 |
1.6490 |
1.6434 |
100% |
|
2 |
1.6542 |
1.5787 |
105% |
All samples are within the required isokinicity range of 100 ± 10%.
Table 5.4: Average combustion gas results
|
CO (mg/m3) |
SO2 (mg/m3) |
NO (mg/m3) |
O2 (%) |
NO2 (mg/m3) |
|---|---|---|---|---|
|
11.6 |
<25 |
8.3 |
21.1 |
1.4 |
Table 5.5: Summary results from induction furnace sample 1 filter, rinses and trap
View summary results from induction furnace sample 1 filter, rinses and trap (large table)
Table 5.6: Results from induction furnace (individual congeners sample 1 filter, rinses and trap)
Table 5.7: Summary results from induction furnace sample 2 filter, rinses and trap
View summary results from induction furnace sample 2 filter, rinses and trap (large table)
Table 5.8: Results from induction furnace (individual congeners sample 2 filter, rinses and trap)