Skip to this page's content Skip to access keys
Go to home page [Ministry for the Environment]

Home | Contact us | Related links | Site map

Working
with you
| The
issues
| Laws and
treaties
| State of the
environment
| Publications | About the
Ministry

Figure: Comparison of results obtained with portable emissions sampler and AS/NZS 4012/3

Return to the point in the document where this figure is located.

 

Textural description of figure

This is a scatter plot showing emissions results from NZS4013 in grams per kilogram on the y-axis. Emissions using the portable emissions sampler is given on the x-axis in grams per kilogram. A line of best fit is drawn where y equals 0.989 x with an R squared value of 0.9269.

 

Return to the point in the document where this figure is located.