Return to the point in the document where this table is located.
| Burner |
Manufacturer / retailer |
Type |
Water heater |
Authorised efficiency (%) |
Tested efficiency (NES = 65%) |
Result |
|---|---|---|---|---|---|---|
Contessa AG – Clean Air |
Hewitsons |
FS |
Yes |
66 |
59 |
Fail – moderate |
Firenzo Insert Flush AG (Forte) |
Hewitsons |
I |
No |
67 |
72 |
Pass |
Kent Logfire Max |
BBQ Factory |
I |
No |
66 |
61 |
Undetermined |
Kent Quantum Max |
BBQ Factory |
FS |
No |
69 |
73 |
Pass |
Lady Kitchener |
Hewitsons |
FS |
No |
74 |
70 |
Pass |
Masport LE 4000 Provincial |
Glen Dimplex |
I |
No |
67 |
61 |
Undetermined |
Metro Eco Wee Rad |
Pioneer |
FS |
No |
70 |
66 |
Pass |
Osburn 2200 |
Glen Dimplex |
FS |
Yes |
68 |
58 |
Fail – moderate |
Woodsman Matai ECR |
WH Harris |
FS |
No |
72 |
64 |
Undetermined |
Yunca Finz |
Yunca Gas |
FS |
No |
65 |
60 |
Undetermined |
Notes: FS = Freestanding; I = Insert.