Return to the point in the document where this table is located.
| Burner |
Manufacturer / retailer |
Type |
Water heater |
Authorised emissions (g/kg) |
Tested emissions ( NES = 1.5g/kg) |
Result |
|---|---|---|---|---|---|---|
Contessa AG – Clean Air |
Hewitsons |
FS |
Yes |
0.86 |
1.39 |
Pass1 |
Firenzo Insert Flush AG (Forte) |
Hewitsons |
I |
No |
0.8 |
2.53 |
Fail – moderate |
Kent Logfire Max |
BBQ Factory |
I |
No |
1.2 |
1.97 |
Fail – minor |
Kent Quantum Max |
BBQ Factory |
FS |
No |
0.54 |
3.51 |
Fail – serious |
Lady Kitchener |
Hewitsons |
FS |
No |
1.42 |
0.63 |
Pass2 |
Masport LE 4000 Provincial |
Glen Dimplex |
I |
No |
0.62 |
1.11 |
Pass1 |
Metro Eco Wee Rad |
Pioneer |
FS |
No |
0.88 |
1.23 |
Pass1 |
Osburn 2200 |
Glen Dimplex |
FS |
Yes |
1.2 |
1.15 |
Pass |
Woodsman Matai ECR |
WH Harris |
FS |
No |
0.8 |
0.8 |
Pass |
Yunca Finz |
Yunca Gas |
FS |
No |
1.33 |
1.65 |
Undetermined |
Notes: FS = Freestanding; I = Insert.
1 This burner meets the NES for air quality criterion but, due to design changes, is incompatible with its authorisation with Environment Canterbury and exceeds the standard of 1.0 g/kg for which it is authorised.
2 This burner meets the NES for air quality criterion but, due to design changes, is incompatible with its authorisation with Nelson City Council.