Skip to main content.

Table 4: Phase 2 detailed results by burner

Return to the point in the document where this table is located.

Burner

Manufacturer/ retailer

Type

Water heater

Design verification

Efficiency

Emissions

Overall classification

Contessa AG – clean air (wet)

Hewitsons

FS

Yes

Fail – serious

Fail – moderate

Pass1

Fail – moderate

Firenzo Insert Flush AG (Forte)

Hewitsons

I

No

Fail – serious

Pass

Fail – moderate

Fail – moderate

Kent Logfire Max

BBQ Factory

I

No

Fail – minor

Undetermined

Fail – minor

Fail – minor2

Kent Quantum Max

BBQ Factory

FS

No

Fail – very serious

Pass

Fail – serious

Fail – very serious

Lady Kitchener

Hewitsons

FS

No

Fail – serious

Pass

Pass

Pass3

Masport LE 4000 Provincial

Glen Dimplex

I

No

Pass

Undetermined

Pass1

Undetermined

Metro Eco Wee Rad

Pioneer

FS

No

Fail – moderate

Pass

Pass1

Pass

Osburn 2200

Glen Dimplex

FS

Yes

Fail – moderate

Fail – moderate

Pass

Fail – moderate

Woodsman Matai ECR

WH Harris

FS

No

Fail – minor4

Undetermined

Pass

Fail – minor

Yunca Finz

Yunca Gas

FS

No

Fail – serious

Undetermined

Undetermined

Fail – serious

Notes: FS = Freestanding; I = Insert.

  1. This burner meets some or all of the NES criteria but, due to design changes, is incompatible with its authorisation with Environment Canterbury and exceeds the standard of 1.0 g/kg for which it is authorised.
  2. This burner was initially classified as a moderate failure. For full details see text.
  3. This burner meets the NES for air quality criteria but, due to design changes, is incompatible with its authorisation with Nelson City Council.
  4. The design verification was initially classified as a moderate failure. For full details see text.