Skip to main content.

Table 3: Full design verification test results

Return to the point in the document where this table is located.

Manufacturer

Model

Type

Water heater

Result

Grade

Outcome

BBQ Factory

Kent Astron CA

FS

No

Pass

 

Pass first time

Dallas Metal Industries Ltd

Kent Kiwi Radiant Clean Air / Milan Caldo Rustic Harmony Clean Air

FS

No

Pass

 

Pass first time

Dallas Metal Industries Ltd

Kent Logfire Max / Milan Harmony I/B

IB

No

Pass

 

Pass first time

Dallas Metal Industries Ltd

Milan Caldo C/A Harmony Series

FS

No

Pass

 

Pass first time

Dallas Metal Industries Ltd

Milan Milano

FS

No

Fail

Minor

Resolved or fixed

Hewitsons Enviro-Heat Ltd

Contessa AG with Water Heating

FS

Yes

Pass

 

Pass first time

Hewitsons Enviro-Heat Ltd

Contessa AG - Clean Air

FS

Yes

Fail

Serious

Unresolved

Hewitsons Enviro-Heat Ltd

Contessa AG - Clean Air

FS

No

Fail

Serious

Unresolved

Hewitsons Enviro-Heat Ltd

Firenzo Bay (with Forte fascia)

IB

No

 

Undetermineda

Unresolved

Hewitsons Enviro-Heat Ltd

Lady Kitchener EF

FS

Yes

Pass

 

Pass first time

Hewitsons Ltd

Bronte Top Outlet AG

FS

No

Fail

Minor

Unresolved

Hewitsons Ltd

Dante

FS

No

Fail

Moderate

Unresolved

Hewitsons Ltd

Deco SD Insert

IB

No

 

Undetermineda

Unresolved

Lansdowne Resource Ltd

Sintes Ethos FS101

FS

No

Fail

Minor

Resolved or fixed

Masport

Masport LE2000 Series 2

FS

No

Pass

   

Masport

Masport Siena

FS

No

Pass

   

Masport

Masport Verona

FS

No

 

Undetermineda

Unresolved

Masport

LE4000

IB

No

Pass

   

MetalFab Industries Ltd

Logaire Atlanta

FS

No

Fail

Seriousb

Unresolved

MetalFab Industries Ltd

Logaire Hestia Clean Air

FS

No

Fail

Seriousb

Unresolved

MetalFab Industries Ltd

Logaire Micros

FS

No

Fail

Seriousb

Unresolved

MetalFab Industries Ltd

Osburn 2200

FS

No

Fail

Seriousb

Unresolved

Pioneer Manufacturing

Metro Eco (with Trend or Trad fascia options)

IB

No

Fail

Minor

Resolved or fixed

Pioneer Manufacturing

Metro Eco Pioneer Pedestal

FS

No

Fail

Minor

Resolved or fixed

Pioneer Manufacturing

Metro Eco Wee Rad

FS

No

Fail

Minor

Resolved or fixed

Pioneer Manufacturing Ltd

Metro ECO Aspire

FS

No

Fail

Minor

Resolved or fixed

Retail Links

Jayline Classic CA

FS

No

Fail

Minor

Resolved or fixed

The Fireplace

Quadra-Fire 2100 Millennium

FS

No

Fail

Minor

Resolved or fixed

The Fireplace

Quadra-Fire 4300 Millennium

FS

No

Fail

Minor

Resolved or fixed

Tropicair Heating Ltd

Tropicair Kowhai 2000 Mk III

FS

No

Fail

Moderate

Resolved or fixed

Tropicair Heating Ltd

Tropicair Tawa Mk III (with flue shield)

IB

No

Fail

Minor

Resolved or fixed

WH Harris Ltd

Nestor Martin R33

FS

No

Pass

 

Pass first time

WH Harris Ltd

Woodsman Matai DVI -165 Standard

IB

No

Pass

 

Pass first time

WH Harris Ltd

Woodsman Miami - 165

FS

No

Pass

 

Pass first time

WH Harris Ltd

Woodsman Pelorus - 165

FS

No

Pass

 

Pass first time

Notes

FS = freestanding burner

IB = inbuilt burner

a Due to a lack of access the burner was not able to be physically inspected and was classified as undetermined.

b A number of MetalFab/Masport burners were classified as moderate failures in the initial review. These were later upgraded to a serious classification due to a delayed response by the manufacturer. This action was in accordance with the protocol agreed to by industry before beginning the review.